Home > Buy Now > Other Manufacturing & Processing Machinery > Diode Laser & Plasma Fiber System for Herniated Disk
 


REV-MED Inc.
 
icon Product

line

icon Company Profile
icon About REV-MED Inc.
icon Marketing materials
icon Education center
icon Index
icon Bulletin Board
icon Guest Book

line



visitors: 466
 
Contact us
REV-MED Inc.
[Korea]
Address:
3F, PoongYang Building, Gaepo-dong, Gangnam-gu, Seoul Korea
Phone:
82-2-5740996
Contact name:
Edward, Shin , Overseas Sales Director
Inquire now









REV-MED Inc.
 
Product

Diode Laser & Plasma Fiber System for Herniated Disk

Inquire now

Diode Laser & Plasma Fiber System for Herniated Disk

Click to enlarge image

 Model Number PLASMAD30

Catalogue PDF file (Click Now!)

1. PDCT laser system for herniated disk

What is PDCT system

   As a 5th generation laser supplementing copernicanly demerits of the existing(conventional) laser intervertebral disc coagulation, it uses patented plasma fibers specifically developed in order to attack only the selected target areas to protect any damage on the unwanted areas from the strongly straight laser.

Making use of a 0.4cm diameter worldly-smallest plasma fiber, it makes a minimally invasive treatment with no scar left and no bleeding available at the time of a herniated disc treatment. Primarily it irradiates a ray source to the center of a nucleus pulposus to reduce the internal pressure and secondarily it is available directly to fire precisely on the protruded annualus areas to firmly fix the stretched annualus to protect any relapsable disc herniation fundamentally.

Merits of PDCT system

  • Safe surgery unlike the established laser, that is, the light source does not go straight but stays at the targeted area to result in almost no heat damage to the peripheral areas.
  • Increased production and coagulation is so superior that it is possible to make volume reduction of the disc nucleus pulposus and firmly solidify tissues of the expanded annualus area.
  • Its effect was maximized than the conventionally used general laser, and it's proud of its copernican simple surgery method than the one using radio frequency.
  • Short surgical time within 30 minutes.
  • No dissection and no bleeding make it possible (for a patient) to get back home(leave the hospital) right after the surgery.

Specification

 

 

1. 980nm

2. Output : 30W

 

3. Spot size : 200um / 400um / 600um / 800um

4. Aimming beam : 2mW  650 nm

5. Platform size : 410 X 250 X 150

6. Electrical power : AC 220 ~ 240V 50/60Hz 1.5KW

                          AC 100 ~ 110V 50/60Hz 3KW

7. Pulse duration

- CW mode : continuous

- Repeat mode : on time 1~1000ms, off time 1~1000ms

- Group Repeat mode : on time 1~1000ms, off time 1~1000ms

  Groupon 1~1000ms, Group-off 1~100ms


Certificate

 

 

   1) ISO 9001

   2) ISO 13485

   3) KFDA

   4) KGMP

 

 

Please contact us for more information.

3. M.D's opinion about PDCT system




Inquire now